Non-Destructive Testing · Industrial CT
See every defect.
Touch nothing.
CT-based NDT maps the full internal volume of your part — porosity, cracks, voids, inclusions — without cutting, drilling, or destroying the sample. Every defect. Every location. In three dimensions.
10µm
Min. detectable feature
2×
Scan modalities
100%
Volumetric — no sampling
CH · EU
Parts accepted from
ProbeamCT Viewer
3D viewing & analysis · free
What is CT-based NDT?
X-ray computed tomography
for industrial inspection
Need to Find faults? Understand material structure? Distribution of features? Deformation before/after? CT scanning builds a complete 3D picture of your part's interior from thousands of X-ray projections.
Pores · Cracks · Inclusions · Delaminations
Find hidden defects
Every void, crack, inclusion, and delamination — mapped in full 3D without cutting, grinding, or destroying the sample. The part leaves in exactly the condition it arrived. What dye-penetrant and ultrasound miss, CT finds.
Particle analysis · Fibre orientation · Density mapping
Materials analysis
CT reveals internal material structure non-destructively: fibre orientation in short-fibre composites, particle distribution in castings and granulates, corrosion mapping in metallic structures, density gradients in sintered or pressed parts, and wall integrity in multi-layer materials. What used to require sectioning and SEM can now be characterised volumetrically — in 3D, across the whole part.
Root cause starts with CT data
Understand failure
Diagnosing a field or engineering failure? CT gives you the full picture before you draw conclusions. What if you have an assembly potted in epoxy, that doesnt work (anymore)? A PCB failure might trace back to a mechanical stress concentration, a weakened solder joint, local overheating, and eventual open circuit — each step visible in the volumetric data. CT documents the complete internal condition at the moment of failure — no evidence lost, no assumptions made.
Before · After · Compare · Register
Two scans tell the full story
Scan the same part before and after any event — controlled impact, applied load, thermal cycle, accelerated ageing — and you gain more than a damage assessment. You can quantify exactly what changed, where, and by how much: deformation under force, crack initiation and growth, internal state change. External features can be registered and matched between scans, internal structures compared voxel-for-voxel. Two scans are also how you diagnose a test hypothesis, document a manufacturing process change, or prove a design improvement.
Have a part that needs looking inside?
Scanning Capabilities
Two modalities.
One contact point.
Small and precise, or large and dense — both covered. You deal with Probeam regardless of which technology your part requires.
Modality A
Microfocus kV
High-resolution · small to medium parts
X-ray CT at fine focal spot sizes — resolves sub-millimetre features in castings, electronics, plastics, and precision assemblies. Run locally in Schaffhausen for fast turnaround and direct communication.
Modality B
Megavolt CT
High-energy · large and dense parts
Linear accelerator-based CT penetrates thick steel, large castings, and dense assemblies that standard X-ray cannot reach. You ship the part, we deliver the data.
Lab environment: Probeam operates within the Suisse Technology Partners facility in Neuhausen am Rheinfall — an ISO/IEC 17025 accredited materials lab. If CT results point to a need for complementary testing (mechanical, corrosion, damage analysis), that expertise is available on-site.