Metrology · NDT · Megavolt CT · Automotive · Carbon

Pin Bond Verification in a Carbon-Ceramic Brake Disc

The challenge: non-destructively verify the critical bond integrity within the ‘floating’ mount system of a 380 mm carbon-ceramic brake disc.

1

DISC SCANNED

12

PINS INSPECTED SIMULTANEOUSLY

380 mm

PART DIAMETER

1 week

SCAN TO REPORT

360 degrees

UNROLL ANALYSIS

Problem & Method

12 precision-machined bobbin seats: are the ceramic-steel bonds intact?

Probeam Viewer Software allows inspection of all pins simultaneously

Cylindrical Unwrap to check all twelve pins at once

Using a single high-energy CT scan, we performed a full volumetric analysis, employing cylindrical interface mapping, a 360° unroll visualisation, and CT-based metrology to deliver comprehensive, artefact-free answers.

Why Megavolt CT delivers where other systems fail

Steel pins? 380mm of Ceramic composite? What CT can possibly image the interface?

Two factors made even high-end 450 kV conventional CT insufficient. First, at 380 mm diameter the beam path is simply too long — standard CT cannot penetrate without severe beam-hardening artefacts that corrupt data precisely at the pin interfaces. Second, and critically, the high energy beam causes the metal pins to attenuate almost identically to the surrounding carbon-ceramic matrix, eliminating the bright metallic artefact halo that in standard CT creates an unreliable “dead zone” around every pin. Without that dead zone, contact can be assessed with genuine confidence all the way to the pin surface.

High energy CT for large, dense, or multi-material parts — full artefact suppression around metal features.

Are your material interfaces fault free?

Result

no gaps detected

Full contact confirmed at all pins

The carbon-ceramic substrate was found to be fully and uniformly in contact with every metal mounting pin across the complete disc volume. No delamination zones, voids, or separations were identified at any pin interface — at any depth in Z. The high energy beam’s artefact-free reconstruction around the metal pins was essential to reaching this conclusion with confidence.

Probeam CT Viewer

Unroll view provided immediate, unambiguous confirmation

Probeam CT Viewer’s unroll feature rendered the full circumference of the disc into a single flat image, all 12 pins visible side-by-side. The tight, uninterrupted ceramic contact around each pin was clearly legible at a glance — no post-processing or pin-by-pin manual review required. This became the primary deliverable shared with the engineering team.

deviation well within target

System metrology verified

CT-based cylinder fitting returned an actual outer diameter of 380.021 mm against the independently verified reference of 380.0 mm — a deviation of +0.02 mm (20 µm). With a target of ±100 µm, the result came in at less than a quarter of the permitted error budget, confirming that Probeam’s high energy CT system delivers reliable dimensional data even on large, mixed-material parts.